Core Developed Assay Datasheet
Analyte: MICA
Assay Conditions: Serum samples require a 1:5 dilution.
Cross Reactivity
The antibody pair is highly specific and displays insignificant cross reactivity with the following core-developed assays:
SCC, Hsp70, EPCAM, Mammaglobin, PSA
The antibody pair may cross react with other core-developed or commercially available assays.
Standard Curve Range: 6.9-5000pg/ml
Recovery in human serum: 118%
Sensitivity (Minimum Detectable Concentration): 15.4pg/ml
Intra-assay Precision: 3-6%